Angle random walk is a noise characteristic of a gyroscope that describes how the standard deviation of angle error grows with the square root of time when a noisy rate signal is integrated. Angle random walk describes what happens when the noisy rate signal of a gyroscope is integrated to obtain an angle. The white noise accumulates like a random walk, so the standard deviation of the angle error grows with the square root of time. Multiplying ARW by the square root of the elapsed time gives the one-sigma angle error caused by noise alone.
It is the short-term counterpart of bias instability. ARW dominates over averaging times of seconds to minutes, bias instability dominates over longer periods. The accelerometer equivalent is velocity random walk.
On a datasheet it appears as degrees per root hour (deg/sqrt(h)) or degrees per root second (deg/sqrt(s)), and sometimes as a noise density in deg/s per root hertz. Typically, industrial MEMS IMUs show about 0.1 to 0.5 deg/sqrt(h), and tactical-grade units are specified below 0.15 deg/sqrt(h). Consumer MEMS gyroscopes are far higher.
A frequent mistake is mixing units. A value in deg/sqrt(s) is 60 times the same value in deg/sqrt(h), so 0.003 deg/sqrt(s) is about 0.18 deg/sqrt(h). Another mistake is comparing ARW with noise density or rms noise without converting, since the output bandwidth changes the rms figure but not the random walk.